Introduction
The EN1.5-YM Tactical Smoke Generator is a professional-grade, aviation-engine powered smoke deployment system designed for modern military, security, and tactical operations. Its high-temperature, high-speed gas jet disperses both visible and infrared smoke, creating dense concealment for personnel, vehicles, and equipment. Built for rapid deployment, reliability, and versatility, this smoke generator provides superior tactical advantage in the field.
Whether for operational missions, training exercises, or emergency scenarios, the EN1.5-YM ensures effective concealment and infrared countermeasure capabilities, keeping your team and assets safe from observation.
Key Features
Dual Smoke Modes
-
Visible Smoke: High-density smoke output for visual concealment.
-
Infrared Smoke: Adjustable output levels for advanced thermal interference.
Effective Coverage
-
Visible Smoke: Covers areas up to 400m × 30m × 20m.
-
IR Smoke: Effective over 150m × 30m × 15m, capable of masking thermal sensors.
Rapid Deployment
-
Start-Up Time: ≤25 seconds
-
Quick Successive Smoke Deployment: Intervals ≤5 seconds
-
High-Speed Gas Jet: 37,000 rpm ± 2,590 rpm ensures immediate smoke coverage
Portable and Durable
-
Compact Design: Dimensions ≤1,135 mm × 535 mm × 520 mm
-
Lightweight: ≤150 kg, easy for field transport
-
Fuel Efficient: Diesel or aviation kerosene, consumption ≤65 kg/h
-
Robust Construction: Operates in extreme temperatures and humidity, and up to 4,500 m altitude
Applications
Military Operations
-
Conceal troop movements, vehicles, and tactical positions.
-
Protect sensitive assets from surveillance and thermal imaging.
-
Create rapid defensive smoke screens in combat zones.
Security and Law Enforcement
-
Tactical smoke deployment for high-risk operations.
-
Protect critical infrastructure or sensitive areas.
-
Aid in emergency evacuations or crowd control.
Training and Simulation
-
Simulate real-world smoke and infrared interference conditions.
-
Train personnel on thermal countermeasure protocols.
Emergency Response
-
Rapid visual concealment in high-risk areas.
-
Controlled smoke for fire drills or urban training exercises.
Maintenance & Care
-
Regular Inspection: Check fuel, lubricants, and mechanical components before deployment.
-
Lubrication: Use aviation-grade sliding oil (4109/4010) to maintain engine efficiency.
-
Cleaning: Remove residue from smoke agents to ensure consistent output.
-
Storage: Store in dry, temperature-controlled environments (-55℃ to +70℃) to preserve durability.
Technical Specifications
| Parámetro | Especificación |
|---|---|
| Effective Smoke Formation Time | ≥3 minutes |
| Visible Smoke Output | ≥500 kg/h |
| IR Smoke Output | 360/540/720 kg/h adjustable |
| Visible Smoke Coverage | ≥400m × 30m × 20m |
| IR Smoke Coverage | ≥150m × 30m × 15m |
| Rated Speed | 37,000 rpm ± 2,590 rpm |
| Airflow | ≥1.2 kg/s |
| Exhaust Temperature | ≤600℃ |
| Start-Up Time | ≤25 s |
| Interval Between Deployments | ≤5 s |
| Weight | ≤150 kg |
| Dimensions | ≤1,135 mm × 535 mm × 520 mm |
| Tipo de combustible | Diesel or Aviation Kerosene |
| Consumo de combustible | ≤65 kg/h |
| Lubricant | Aviation Oil 4109/4010 |
| Lubricant Consumption | ≤100 ml/h |
| Environmental Range | -40℃ to +50℃ operating; -55℃ to +70℃ storage |
| Max Altitude | ≥4,500 m |
| MTBF | ≥500 hours |
How It Works
-
Load the smoke agent into the generator.
-
Start the engine; high-speed gas jet propels the agent into the air.
-
The system produces dense visible smoke y IR interference smoke simultaneously.
-
Smoke persists in the air, providing concealment or disrupting thermal detection.
-
The generator can be restarted rapidly, allowing continuous coverage during operations.
Why Choose EN1.5-YM?
-
High-Speed Deployment: Fast coverage for urgent tactical scenarios.
-
Dual-Mode Concealment: Combines visible smoke and IR interference for full-spectrum protection.
-
Portable & Easy to Operate: Lightweight and compact for field operations.
-
Reliable & Fuel Efficient: Long operational life with minimal fuel consumption.
-
All-Weather Performance: Functions in extreme temperatures, humidity, and high altitudes.
-
Trusted Brand: Designed and manufactured by Energía RCJetEngine, a leader in tactical smoke systems.
Customer Testimonials
“The EN1.5-YM is a game-changer for our training exercises. Quick deployment, dense smoke, and excellent IR interference.” – Security Operations Manager, UK
“Lightweight, reliable, and easy to operate even in harsh conditions. It has exceeded our expectations in field operations.” – Military Training Officer, US
FAQ
Q1: How long does it take for the smoke screen to form?
A: The generator produces an effective smoke screen within 3 minutes.
Q2: Can it operate at high altitudes?
A: Yes, it is designed to work up to 4,500 meters above sea level.
Q3: What fuels are compatible?
A: Diesel or aviation kerosene.
Q4: How portable is the system?
A: Weighing ≤150 kg with compact dimensions, it can be deployed quickly in the field.
Q5: Is it suitable for training exercises?
A: Absolutely, it simulates both visible and infrared smoke conditions for realistic tactical training.
Energy RCJetEngine Assurance
Every EN1.5-YM Tactical Smoke Generator is designed, tested, and manufactured to ensure rapid deployment, reliable operation, and effective tactical concealment. With advanced visible and infrared smoke capabilities, this system provides peace of mind and tactical advantage for military, security, and emergency applications worldwide.



Valoraciones